Sakthivel, Rathinasamy Samidurai, R. Anthoni, S. Marshal
Sungkyunkwan Univ Dept Math Suwon 440746 South KoreaPeriyar Univ Dept Math Salem 636011 IndiaAnna Univ Coimbatore Dept Math Coimbatore 641047 Tamil Nadu India
摘要:
This paper is concerned with the exponential stability of stochastic neural networks of neutral type with impulsive effects. By employing the Lyapunov functional and stochastic analysis, a new stability criterion for the stochastic neural network is derived in terms of linear matrix inequality. A numerical example is provided to show the effectiveness and applicability of the obtained result.
摘要:
针对传统的基于脉冲耦合神经网络(PCNN)的融合算法中每个神经元链接强度取同一常数的不足,提出了一种基于自适应PCNN图像融合新算法。作为显著性特征,使用像素的拉普拉斯能量(EOL,energy of Lapla-cian)和标准差(SD,standard deviation)分别作为PCNN对应神经元的链接强度值。实验结果表明,本文方法融合结果优于Laplacian方法、小波方法和传统的PCNN方法。
Murr, L. E. Gaytan, S. M. Medina, F. Lopez, H. Martinez, E. Machado, B. I. Hernandez, D. H. Martinez, L. Lopez, M. I. Wicker, R. B. Bracke, J.
Univ Texas El Paso Dept Met & Mat Engn El Paso TX 79968 USAUniv Texas El Paso WM Keck Ctr Innovat 3D El Paso TX 79968 USAUniv Texas El Paso Dept Mech Engn El Paso TX 79968 USAIMCE B-3600 Genk Belgium
摘要:
In this paper, we examine prospects for the manufacture of patient-specific biomedical implants replacing hard tissues (bone), particularly knee and hip stems and large bone (femoral) intramedullary rods, using additive manufacturing (AM) by electron beam melting (EBM). Of particular interest is the fabrication of complex functional (biocompatible) mesh arrays. Mesh elements or unit cells can be divided into different regions in order to use different cell designs in different areas of the component to produce various or continually varying (functionally graded) mesh densities. Numerous design elements have been used to fabricate prototypes by AM using EBM of Ti-6Al-4V powders, where the densities have been compared with the elastic (Young) moduli determined by resonant frequency and damping analysis. Density optimization at the bone-implant interface can allow for bone ingrowth and cementless implant components. Computerized tomography (CT) scans of metal (aluminium alloy) foam have also allowed for the building of Ti-6Al-4V foams by embedding the digital-layered scans in computer-aided design or software models for EBM. Variations in mesh complexity and especially strut (or truss) dimensions alter the cooling and solidification rate, which alters the a-phase (hexagonal close-packed) microstructure by creating mixtures of alpha/alpha' (martensite) observed by optical and electron metallography. Microindentation hardness measurements are characteristic of these microstructures and microstructure mixtures (alpha/alpha') and sizes.